Ground conditions on the site required special attention to the foundation construction to ensure the design was correctly implemented. Structural walls are constructed from a mixture of precast concrete and reinforced masonry with plaster and natural schist stone cladding. The suspended floors are constructed from precast concrete rib & timber infill system supported on structural steel frames and the attic style roof structure is supported by structural steelwork with timber framing intermediate members.